The short answer: if the battery is cycled every day, through daily power cuts or as solar storage, a LiFePO4 battery gives more usable energy per rated kWh, far more cycles and faster recharging, in one unit instead of four. A tubular bank costs less to buy and can still suit a home that only needs backup now and then.
Same inverter, two kinds of battery
A 48 V inverter runs on either. A tubular bank is four 12 V lead-acid batteries in series. A lithium battery for the same inverter is one 51.2 V unit, built from sixteen 3.2 V LiFePO4 cells.
Side by side
| Tubular lead-acid bank | LiFePO4 battery | |
|---|---|---|
| For a 48 V inverter | Four 12 V batteries in series | One 51.2 V unit |
| Example | 4 × 12 V 200 Ah = 9.6 kWh on paper | 51.2 V 200 Ah = 10.24 kWh |
| Energy used day to day | About half: about 4.8 kWh | About 80%: about 8.2 kWh |
| Cycle life | Depends heavily on depth of discharge; check the maker’s figure at the depth you will use | 6,000 cycles at 80% depth of discharge on our KNY 51 series; 8,000 on some 15 and 16 kWh models |
| Recharging | Slows down near full, and needs regular full charges | Takes its recommended current until nearly full: 100 A on our 10–20 kWh units |
| Looking after it | Flooded types need distilled-water top-ups and ventilation | Sealed; a battery management system protects the cells |
| Monitoring | Voltage only | State of charge over CAN / RS485; Bluetooth, WiFi or a touch screen on some models |
| Space | Four batteries side by side | One floor-standing or wall-mounted unit; the 10.24 kWh KNY 51200 weighs 101 kg |
Why usable energy matters more than the label
Four 12 V 200 Ah tubular batteries make 9.6 kWh on paper. They are usually discharged to only about half, to protect their life, so about 4.8 kWh is used each night. A 51.2 V 200 Ah LiFePO4 battery stores 10.24 kWh and gives about 8.2 kWh at 80%. With a similar label, the lithium battery delivers about 1.7 times the energy per night.
| Battery | On paper | Used each night | Hours at 500 W |
|---|---|---|---|
| Tubular, 4 × 12 V 200 Ah | 9.6 kWh | 4.8 kWh | 8.6 h |
| LiFePO4, 51.2 V 200 Ah | 10.24 kWh | 8.2 kWh | 14.7 h |
When tubular still makes sense
- Power cuts are rare and short, so the battery is seldom cycled.
- The budget for the battery itself is the deciding factor today.
- The inverter cannot be set for lithium and will not be replaced.
Switching an existing inverter to lithium
- Replace the whole 12 V bank with one 51.2 V unit. Do not mix lithium and lead-acid batteries in one bank.
- Set the battery type to lithium, or connect the CAN / RS485 cable so the inverter reads the battery’s state of charge directly.
- If you set the values by hand: charge voltage 58 V recommended and never above 58.4 V; low-battery cut-off at the battery’s recommended value, 44–46 V on our 51.2 V models.
- Set the maximum charge current to the battery’s recommended figure: 100 A on our 10–20 kWh units.
See what size battery a 5 KVA inverter needs for sizing by inverter.