Guide · 3 min read

How many Ah is a 16 kWh battery?

At 51.2 V, about 312 Ah; our 16.08 kWh models use 314 Ah cells. Here is the formula, a table for every common size, and why the voltage changes the answer.

The short answer: at 51.2 V, the voltage of a “48 V” LiFePO4 battery, a 16 kWh battery holds about 312 Ah. Our 16.08 kWh models use 314 Ah cells: 51.2 V × 314 Ah = 16,077 Wh.

The formula

Ah = Wh ÷ V, and the other way round, kWh = V × Ah ÷ 1,000. Amp-hours on their own say nothing about energy until you know the voltage, so always compare batteries in kWh, or in Ah at the same voltage.

Common 51.2 V sizes

Capacity (Ah) at 51.2 VEnergyOur batteries
100 Ah5.12 kWh5 kWh batteries
120 Ah6.14 kWhAU51120
200 Ah10.24 kWh10 kWh batteries
280 Ah14.34 kWh—
300 Ah15.36 kWhKNY-P51300 and other 15 kWh models
314 Ah16.08 kWh16 kWh batteries
400 Ah20.48 kWh20 kWh batteries

51.2 V is 16 LiFePO4 cells of 3.2 V in series. Batteries sold as “48 V lithium” are almost always 51.2 V.

Why the voltage changes the answer

The same 16 kWh of energy is a very different number of amp-hours at each system voltage:

System voltageAmp-hours for 16 kWh
12.8 V1,250 Ah
25.6 V625 Ah
48 V333 Ah
51.2 V312 Ah

If you divide by 48 V instead of 51.2 V you get about 333 Ah, which is why a “16 kWh” lithium battery and a “48 V 333 Ah” calculation do not match. LiFePO4 batteries are built from 3.2 V cells, so 51.2 V is the figure to use.

Usable amp-hours

Cycle life is usually rated at 80% depth of discharge, so plan to use about 80% of the rated capacity: about 250 Ah from a 314 Ah battery, or about 160 Ah from a 200 Ah battery.

BatteryAh at 51.2 VUsable at 80%
5 kWh98 Ah78 Ah · 4.0 kWh
10 kWh195 Ah156 Ah · 8.0 kWh
15 kWh293 Ah234 Ah · 12.0 kWh
16 kWh312 Ah250 Ah · 12.8 kWh
20 kWh391 Ah312 Ah · 16.0 kWh

Comparing with a lead-acid or tubular bank

Four 12 V 200 Ah lead-acid batteries in series make a 48 V, 200 Ah bank: 9.6 kWh on paper. Lead-acid batteries are usually discharged only to about half, to protect their life, so about 4.8 kWh is used day to day. A 51.2 V 200 Ah LiFePO4 battery stores 10.24 kWh and gives about 8.2 kWh at 80%, from one unit instead of four.

Amp-hours and current are different things

Ah tells you how much charge the battery stores; amps tell you how fast it is drawn. A 314 Ah battery does not deliver 314 A. Our 10–20 kWh units are rated 100 A recommended and 200 A maximum, and at 51.2 V every kW of inverter output draws about 20 A. See how many kWh a home needs for sizing by load.

Need help sizing a system?

Send us the loads, the inverter and the market. We recommend a battery and reply with the datasheet and price.

WhatsApp